Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
---|---|
Output Type: | Triple |
Principle of Work: | V/F Control Transducer |
Customization: |
---|
Shipping Cost:
Estimated freight per unit. |
about shipping cost and estimated delivery time. |
---|
Payment Method: | |
---|---|
Initial Payment Full Payment |
Currency: | US$ |
---|
Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
---|
Suppliers with verified business licenses
Performance is remarkable
Current vector control algorithm, strong load capacity, fast response speed, wide speed range
Wide voltage input
When the power grid voltage and frequency fluctuate, automatically adjust the output, small impact on the motor and production machinery;
Widely used
Covers a variety of typical load application functions to meet the needs of various applications; Built-in brake unit
Compact, built-in brake unit (18.5KW and below standard)
RS485 communication
Standard RS485 serial communication interface, standard MODBUS communication protocol;
Complete protection performance
Overcurrent, overvoltage, input phase loss, output phase loss, output imbalance detection and other protection functions
High safety
Mature and reliable structure design, high flame retardant material, to ensure product safety.
The main parameters
Item |
Description |
||
Output |
Output voltage |
0V to the input voltage |
|
Output frequency |
Low - frequency mode : 0.00Hz to 500.00Hz |
||
Carrier frequency |
0.8khz to 16.0khz (automatic adjustment according to the load) |
||
Overload capacity |
150% / 1 min |
||
Input |
Voltage/Frequency |
3-phase: 380V; 50/60Hz |
|
the fluctuation of |
3-phase: 380V AC ±15%, allowable range: 323V AC to 437V AC |
||
Frequency range |
G type: 110% for long-term, 120% for 22 min, 150% for 1min |
||
Control |
Frequency Setting |
Analog Input |
0.025% of maximum output frequency |
Digital Setting |
0.01 Hz |
||
Control mode |
Voltage/Frequency (V/F) control, Sensorless vector control (SVC) and Feedback vector control (FVC) |
||
Startup torque |
SVC |
0.25 Hz/150% |
|
FVC |
0 Hz/180% |
||
Speed range |
SVC |
1:200 |
|
FVC |
1:1000 |
||
Speed stability |
SVC |
±0.5% (SVC) |
|
FVC |
±0.02% (FVC) |
||
Torque boost |
Customized boost 0.0 % to 30.0 % |
||
V/F curve |
Straight-line V/F curve, Multi-point V/F curve, Complete V/Fseparation and Half V/F separation |
||
Wave current limit |
In V/F mode, to achieve fast response and ensure the normal operation of the inverter |
||
Ramp mode |
Straight-line ramp, S-curve ramp Four separate acceleration/deceleration time: 0.1s to 6500s |
||
Automatic voltage |
The system maintains a constant output voltage automatically when the grid voltage changes through the permissible range. |
||
DC injection braking |
DC injection braking frequency: 0 Hz to max frequency |
||
Jog running |
Frequency range of jog running: 0.00 to 50.00 Hz |
||
Onboard multiple |
The system implements up to 16 speeds by using simple PLC function or by using digital input signals. |
||
Overvoltage and |
Overvoltage and overcurrent stall control |
||
Torque limit and |
The system limits the torque automatically. |
||
Undervoltage |
Specially for users with a low or unsteady voltage power grid: even lower than the allowable voltage range, the system can maintain the longest possible operating time based on its unique algorithm and residual energy allocation strategy |
||
Control input |
Command source |
Allows different methods of switching between command sources: |
|
Main frequency |
Allows different methods of switching between frequency reference setting channels: Digital setting, Analog voltage reference, Analog current reference, Pulse reference, Communication reference |
||
Auxiliary frequency |
Allows fine tuning of the auxiliary frequency and main & auxiliary |
||
Input terminals |
0 to 5V keyboard potentiometer input Six digital input (X) terminals, one of which supports up to 50 kHz high-speed |
||
Output terminals |
Single high-speed pulse output terminal (open-collector) for a square-wave signal |
||
serial |
RS-485 interface |
||
Protective Function |
Overcurrent, overvoltage, Undervoltage, module fault, electric thermal relay, overheat, short circuit, default phase of input and output, motor parameter adjustment abnormality, internal memory fault, etc. |
||
Display |
Five digit digital |
Parameter setting: |
Function code, |
Running state display: |
|||
Fault display: Display the fault code. |
|||
Environment |
Installation location |
Install the inverter where it is indoors and protected from direct sunlight, |
|
Ambient |
-10°C to +40°C (please run the VFD in derated capacity when ambient |
||
Ambient Humidity |
20% to 95%RH, without condensing drops |
||
Operation |
-10°C to +50°C |
||
Vibration |
Less than 0.5 g |
||
Storage |
-25°C to +65°C |
||
Installation Method |
Wall-hanging type, cabinet type |
||
Structure |
Protection Level |
IP20 |
|
Cooling Method |
Air cooling with fan control |